<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>al</ParameterFamily>
<LongName>
table_vac_threshold
</LongName>
<Name>
tvt
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Trendsetter_VLF</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_VLF_Auto</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
Sets the minimum allowable vacuum pressure level for the firmware to believe
that a plate is being held by the table vacuum.  When the measured vacuum
pressure is below this parameter, the firmware will not believe that a plate is
on the load/unload table.  The vacuum is only checked at the beginning of the
load cycle, before the table is lifted up.
</text></DescriptionText>
</Description>
<Type>
word
</Type>
<Default>
<UnnumberedList>
<li>200</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 1024 (no units)</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
Typically there should be no need to adjust this parameter, as there is
plenty of difference in the vacuum level between when there is and isn't a
plate covering the vacuum holes.
</text></DescriptionText>
</Notes>
<Partition>
cal
</Partition>
<SeeAlso>
<UnnumberedList>
<ListItem><Text>command: table vac</Text></ListItem>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:35:43 2008 PST
</Updated>
<Links>
</Links>
</Parameter>